heavy oil steam gnerator

Industrial boilers

Product thermal capacity: 4-35 t/h

Working pressure: 1.0-2.5 MPA

Outlet temperature: 184-350 ℃

Available fuel: natural gas, coke oven gas, bio-gas,liquid propane gas, diesel, heavy oil, light oil, crude oil

Available industries: Petroleum, chemical, chemical fiber, pharmaceutical, textile printing and dyeing, building materials, wood processing, vegetable oil processing and other industries

  • Product introduction
  • Technical advantages
Introduction

heavy oil steam gnerator have a three-pass round coil structure. A conical coil is used for the effective protection of the furnace wall at the boiler end. This product is equipped with an advanced combustion device and is fully automated in operation. After the burner ignites the fuel, flame fills the round coil tubes and transfers heat by radiation through the tube wall (first pass). The high temperature flue gas gathers at the back door and then turns to the convection tubes section (second pass), where heat transfer takes place by convection. The flue gas gradually cools down here and flows to the front door, where it is reversed and goes into the third pass. After that, it enters into the chimney through the economizer and is released into the atmosphere.


heavy oil steam gnerator.This type of heater is delivered as a whole, and is installed on site, it only needs to connect thermal gas(oil) piping and electricity to start operation. The heater has four heating areas: furnace radiation heating area, the first convection tube bundle heating area, the second convection tube bundle heating area and economizer (waste heat boiler).

Digitized manufacture
  • The laying-off of steel tube adopts CNC 3D laser cutting machine.
  • The manufacture of round coil tube adopts CNC coil tube automatic production line. Once-forming and no need for plastic .
Full argon arc welding
  • The tube butt adopts argon arc welding technique and the seams will be done x ray real-time imaging, preventing unqualified seams from entering coil production line .
Easy operation
  • Heater is wholly assembled before delivery, it is easy for installation, debugging and operating.
  • Fully automatic operating, burning, liquid level of high level tank, outlet temperature and flow rate are adjusted automatically and self-protected.
  • The inlet and outlet with end flanges and flanged cover structure facilitate the installation and layout of tubeline in boiler house.
Less fuel consumption
  • Internal side adopts good insulation material, outside uses stainless steel plate, which can mostly reduce heat lost and make working environment better.
  • Multilayers closely spaced tube bundle and steel rod is used to seal and fix, completely eradicating short circuit of flue gas.
  • Before delivery, the residue moisture is removed completely, so the system draining period is reduced to 2 days from 12 days.
Safely operation
  • The inner coil tube has bigger flow rate, so it is more stable under high temperature operation.
  • Conical coil effectively protects the furnace wall at the end of heater and burner on the top.
heavy oil steam gnerator heavy oil steam gnerator heavy oil steam gnerator

japan boiler | Product - elmalihaber.o

TECHNICAL ADVANTAGES. Boiler body uses the forced circulation in the high temperature area to make sure all heating areas can be cooled down and avoid vaporization; The explosion door and flame detector are equipped for safe and reliable operation.

lexie@zozen.com > Get A Quote >

Generators | Power Generation | Sieme

Generators from 0.3 up to 2,235 MVA Siemens generators are the perfect solution wherever power has to be generated quickly, reliably and efficiently – whether on board of a ship or on an oil platform, in an industrial plant, a large gas or steam power plant or for renewables.

lexie@zozen.com > Get A Quote >

Comparing Natural Gas and Diesel Generator Sets - Powe

While the fall in natural gas prices is certainly making them a more attractive option, plummeting oil prices are having a similar effect on diesel generator fuel. We won't make a prediction here

lexie@zozen.com > Get A Quote >

A waste heat recovery steam power generation system fo

A waste heat recovery steam power generation system for ACE Power Embilipitiya (Pvt) Ltd, Sri Lanka. of 100MW comprising 14 units of 7.5MW medium speed diesel engines fired with heavy fuel oil. There is only a minimum recovery of waste heat in the plant at the moment, only 2.6 Steam Turbine

lexie@zozen.com > Get A Quote >

WATER-COOLED STATOR WINDINGS COPPER OXIDE ISSUES

WATER-COOLED STATOR WINDINGS COPPER OXIDE ISSUES Clyde V. Maughan, President Maughan Generator Consultants Schenectady, NY, USA 1954; the initial liquid was transil oil, the oil used in transformers. However, because of viscosity and other issues, water was a more heavy and prominent, leaving oxide buildup the prime suspect as root cause.

lexie@zozen.com > Get A Quote >

Generator Covers | Coverstore

Generator Covers Keep your generator ready to use when you need it by investing in one of our water-resistant, durable portable generator covers. Available in multiple size, style, and material combinations, you are sure to find the perfect fitting protection.

lexie@zozen.com > Get A Quote >

Generator Service and Maintenance | Generator Informati

Wait until the coolant temperature is below 120°F (50°C) before removing pressure cap. Heated coolant spray or steam can cause injury. All planned maintenance charts define checks to be completed at a calendar interval. Coolant, lubricating oil and coolant levels can be …

lexie@zozen.com > Get A Quote >

Gas Turbines | Manufacturer | Power Generation | Sieme

They also perform well in decentralized power generation applications. Their high steam-raising capabilities help achieve overall plant efficiency of 80 percent or higher. They are proven with more than 2,250 units sold at small utilities, independent power producers, and in the oil and gas industry.

lexie@zozen.com > Get A Quote >

Boiler (power generation) - Wikiped

A boiler or steam generator is a device used to create steam by applying heat energy to water.Although the definitions are somewhat flexible, it can be said that older steam generators were commonly termed boilers and worked at low to medium pressure (7–2,000 kPa or 1–290 psi) but, at pressures above this, it is more usual to speak of a steam generator.

lexie@zozen.com > Get A Quote >

Alternative Fuels | Cummins In

Flare gas: flammable gases and vapors from oil exploration activities; Biodiesel: diesel fuel mixed with up to 10 percent of oils and fats from plant or animal sources, burned in an unmodified diesel generator; For information or solutions for your cogeneration needs, please contact our Power Solutions group.

lexie@zozen.com > Get A Quote >

Steam Generation Suggested Actions - Department of Ener

Benchmarking the fuel cost of steam generation, in dollars per 1,000 pounds ($/1,000 lb) of steam, is an effective way to assess the efficiency of your steam system. This cost is dependent upon fuel type, unit fuel cost, boiler efficiency, feedwater temperature, and steam pressure.

lexie@zozen.com > Get A Quote >