domestic air to water hot water boiler high cop seer unit

Industrial boilers

Product thermal capacity: 4-35 t/h

Working pressure: 1.0-2.5 MPA

Outlet temperature: 184-350 ℃

Available fuel: natural gas, coke oven gas, bio-gas,liquid propane gas, diesel, heavy oil, light oil, crude oil

Available industries: Petroleum, chemical, chemical fiber, pharmaceutical, textile printing and dyeing, building materials, wood processing, vegetable oil processing and other industries

  • Product introduction
  • Technical advantages
Introduction

domestic air to water hot water boiler high cop seer unit have a three-pass round coil structure. A conical coil is used for the effective protection of the furnace wall at the boiler end. This product is equipped with an advanced combustion device and is fully automated in operation. After the burner ignites the fuel, flame fills the round coil tubes and transfers heat by radiation through the tube wall (first pass). The high temperature flue gas gathers at the back door and then turns to the convection tubes section (second pass), where heat transfer takes place by convection. The flue gas gradually cools down here and flows to the front door, where it is reversed and goes into the third pass. After that, it enters into the chimney through the economizer and is released into the atmosphere.


domestic air to water hot water boiler high cop seer unit.This type of heater is delivered as a whole, and is installed on site, it only needs to connect thermal gas(oil) piping and electricity to start operation. The heater has four heating areas: furnace radiation heating area, the first convection tube bundle heating area, the second convection tube bundle heating area and economizer (waste heat boiler).

Digitized manufacture
  • The laying-off of steel tube adopts CNC 3D laser cutting machine.
  • The manufacture of round coil tube adopts CNC coil tube automatic production line. Once-forming and no need for plastic .
Full argon arc welding
  • The tube butt adopts argon arc welding technique and the seams will be done x ray real-time imaging, preventing unqualified seams from entering coil production line .
Easy operation
  • Heater is wholly assembled before delivery, it is easy for installation, debugging and operating.
  • Fully automatic operating, burning, liquid level of high level tank, outlet temperature and flow rate are adjusted automatically and self-protected.
  • The inlet and outlet with end flanges and flanged cover structure facilitate the installation and layout of tubeline in boiler house.
Less fuel consumption
  • Internal side adopts good insulation material, outside uses stainless steel plate, which can mostly reduce heat lost and make working environment better.
  • Multilayers closely spaced tube bundle and steel rod is used to seal and fix, completely eradicating short circuit of flue gas.
  • Before delivery, the residue moisture is removed completely, so the system draining period is reduced to 2 days from 12 days.
Safely operation
  • The inner coil tube has bigger flow rate, so it is more stable under high temperature operation.
  • Conical coil effectively protects the furnace wall at the end of heater and burner on the top.
domestic air to water hot water boiler high cop seer unit domestic air to water hot water boiler high cop seer unit domestic air to water hot water boiler high cop seer unit

solar heat pumps heater - alibaba.c

Alibaba.com offers 704 solar heat pumps heater products. About 1% of these are hvac systems & parts. A wide variety of solar heat pumps heater options are available to you, such as ce, cb, and ul.

lexie@zozen.com > Get A Quote >

Air Conditioner Water Heaters | AC/Heat Pumps That Mak

A full featured ultra high efficiency air conditioner with remote control, this system captures heat that is normally thrown away and uses it to make free hot water. Remote Control ACWH Outdoor Unit

lexie@zozen.com > Get A Quote >

Cooling and Heating - Performance and Efficiency Terminolo

Example - Hot Water Radiator System. COP = 500 q dt / 3143 P (1) where . q = hot water flow (gal/min) dt = temperature difference between supply and return water (o F) P = input power to pump (kW) EER - Energy Efficiency Ratio. Room air conditioners in general range …

lexie@zozen.com > Get A Quote >

Boilers vs Heat Pumps Comparison (2019) | GreenMat

A boiler is a sealed chamber device, wherein the coolant (usually a water based solution or water steam) is heated to a predetermined temperature, which is later used to generate heat and provide hot water. When looking for a boiler, one might want to consider the following technical parameters that will help the customer easily compare boilers

lexie@zozen.com > Get A Quote >

evi air water heat pump, View evi air water heat pum

Evi air water heat pump . HISEER evi air water heat pump AW13/L , can be used at -25 degree ambient temperature. AW/L series heat pump use well selected and tested world famous brand components to assure stable and efficient performance. AW/L series heat pump can control a 3 way valve to divert AW13/L house heating and producing domestic hot water.

lexie@zozen.com > Get A Quote >

Heating, ventilation, and air conditioning - Wikiped

Most modern hot water boiler heating systems have a circulator, which is a pump, to move hot water through the distribution system (as opposed to older gravity-fed systems). The heat can be transferred to the surrounding air using radiators, hot water coils (hydro-air), or other heat exchangers. The radiators may be mounted on walls or

lexie@zozen.com > Get A Quote >

firewood pellet hot water boiler - flashpoints.com.

domestic air to water hot water boiler high cop seer unit; biomass waste steam boiler; class a fixed grate wood pellet wood chip sawdust steam boiler; quick start steam boiler; Industrial 2000 kg hr heavy fuel oil-fired steam boiler; hot water boilers for chile; steam boiler singapore; environmental chain stocker boiler; whch boiler usd in

lexie@zozen.com > Get A Quote >

Condensing Gas Boiler Foreign - capoberta.

Domestic Air To Water Hot Water Boiler High Cop Seer Unit. Air to Water Gas Hybrid Daikin Altherma hybrid heat pump Easy and fast installation Components • Heat pump outdoor unit • Heat pump indoor unit • Gas condensing boiler As the heat pump indoor unit and gas condensing boiler are delivered as …

lexie@zozen.com > Get A Quote >

Foreign Boiler Electric Water - capoberta.

Domestic Air To Water Hot Water Boiler High Cop Seer Unit. 10kw air to water chiller Related Post air cold biomass burner for steam boiler and hot water boiler domestic air to water hot water boiler high cop seer unit electric deluxe water heating jug szl rice husk fired hot water boiler propane gas fired hot water boiler 6 Learn .

lexie@zozen.com > Get A Quote >

HEAT PUMPS May 2017 HEAT PUMP SPLIT AIR WATER HOT AND

HEAT PUMP SPLIT, AIR /WATER, HOT AND COLD REVERSIBLE WIT H INTEGRATED D HW STORAGE TANK HPC Description HPC heat pumps are high efficiency heating and cooling systems for residential buildings. HPC heat pumps are already provided with technical storage tank for domestic hot water (DHW) instantaneous production thus making the

lexie@zozen.com > Get A Quote >

Hot water boilers - Calvert Mechanic

Domestic hot water is the heater man’s term when the boiler is used to heat the house and the water used for cooking, cleaning and bathing, (potable water). Boiler water is nasty and would make you sick should you accidently drink it, so the potable water and boiler water are kept separate in a manner that’s impossible to cross contaminate.

lexie@zozen.com > Get A Quote >