low pressure type hot water boiler

Industrial boilers

Product thermal capacity: 4-35 t/h

Working pressure: 1.0-2.5 MPA

Outlet temperature: 184-350 ℃

Available fuel: natural gas, coke oven gas, bio-gas,liquid propane gas, diesel, heavy oil, light oil, crude oil

Available industries: Petroleum, chemical, chemical fiber, pharmaceutical, textile printing and dyeing, building materials, wood processing, vegetable oil processing and other industries

  • Product introduction
  • Technical advantages
Introduction

low pressure type hot water boiler have a three-pass round coil structure. A conical coil is used for the effective protection of the furnace wall at the boiler end. This product is equipped with an advanced combustion device and is fully automated in operation. After the burner ignites the fuel, flame fills the round coil tubes and transfers heat by radiation through the tube wall (first pass). The high temperature flue gas gathers at the back door and then turns to the convection tubes section (second pass), where heat transfer takes place by convection. The flue gas gradually cools down here and flows to the front door, where it is reversed and goes into the third pass. After that, it enters into the chimney through the economizer and is released into the atmosphere.


low pressure type hot water boiler.This type of heater is delivered as a whole, and is installed on site, it only needs to connect thermal gas(oil) piping and electricity to start operation. The heater has four heating areas: furnace radiation heating area, the first convection tube bundle heating area, the second convection tube bundle heating area and economizer (waste heat boiler).

Digitized manufacture
  • The laying-off of steel tube adopts CNC 3D laser cutting machine.
  • The manufacture of round coil tube adopts CNC coil tube automatic production line. Once-forming and no need for plastic .
Full argon arc welding
  • The tube butt adopts argon arc welding technique and the seams will be done x ray real-time imaging, preventing unqualified seams from entering coil production line .
Easy operation
  • Heater is wholly assembled before delivery, it is easy for installation, debugging and operating.
  • Fully automatic operating, burning, liquid level of high level tank, outlet temperature and flow rate are adjusted automatically and self-protected.
  • The inlet and outlet with end flanges and flanged cover structure facilitate the installation and layout of tubeline in boiler house.
Less fuel consumption
  • Internal side adopts good insulation material, outside uses stainless steel plate, which can mostly reduce heat lost and make working environment better.
  • Multilayers closely spaced tube bundle and steel rod is used to seal and fix, completely eradicating short circuit of flue gas.
  • Before delivery, the residue moisture is removed completely, so the system draining period is reduced to 2 days from 12 days.
Safely operation
  • The inner coil tube has bigger flow rate, so it is more stable under high temperature operation.
  • Conical coil effectively protects the furnace wall at the end of heater and burner on the top.
low pressure type hot water boiler low pressure type hot water boiler low pressure type hot water boiler

What is the safe pressure for a hot-water-heating syste

Jan 19, 2015 · The water pressure in a hydronic boiler shouldn't be over 12- to 15-psi. It should have only enough pressure to raise the water a few feet above the top of the highest point in the piping system. A 12-psi setting will lift water 28' above the fill valve.

lexie@zozen.com > Get A Quote >

BASIS SAFETY CONTROLS FOR HOT WATER AND LOW

Essentially the construction of a hot water boiler and a steam boiler are the same. Most of the reasons why low water can occur in a steam boiler will also hold true for a hot water boiler. It is a common misconception that a pressure reducing valve, used to fill a hot water …

lexie@zozen.com > Get A Quote >

Difference Between Low- and High-Pressure Boilers | Hunk

In a low-pressure boiler the pressure does not exceed 15 psi, and hot water heating boilers are not designed to exceed over 260 psig. The temperature in a low-pressure boiler will not rise above 250 degrees F.

lexie@zozen.com > Get A Quote >

low pressure package type hot water boiler - degrensvoorbij.

A low pressure hot water heating boiler with a volume of more than 120 gallons, or a heat input of more than 200,000 BTU per hour, or an operating temperature of more than 200° F, that provides water to be used externally to itself.

lexie@zozen.com > Get A Quote >

Boiler Types and Classifications - Wiki - odesie by Tec

Hotwater boilers that have temperatures not exceeding 250° Fahrenheit or pressures not exceeding 160 psig are called ''low temperature hot water boiler''s. Heating boilers are also classified as to the method of manufacture, i.e., by casting ( cast iron boilers ) or fabrication (steel boilers).

lexie@zozen.com > Get A Quote >

The Vitomax low pressure hot water boiler | Viessma

Type M148, low pressure hot water boiler, heating output: 0.65 - 6.0 MW, for permissible flow temperatures up to 110 °C Vitomax 100-LW M148 Type M148, system pack, low pressure hot water boiler, heating output: 0.65 - 6.0 MW, for permissible flow temperatures up to 110 °C

lexie@zozen.com > Get A Quote >

Low pressure boilers, Ch. 1 Flashcards | Quizl

A boiler in which water is heated for purpose of supplying hot water at pressure of not more than 160 psi and temp. of not more than 250 degrees Fahrenheit. Hot Water Supply Boiler Low pressure hot water boiler with a volume of more that 120 gallon or heat input of more than 200,000 BTU/hour or operating temp. of more than 200 degrees

lexie@zozen.com > Get A Quote >

Low hot water pressure from combi boiler - advice pleas

Jul 30, 2008 · Low hot water pressure from combi boiler - advice please. Two weeks ago the hot water flow rate (at all taps) from my combi boiler (Worcester Bosch 24Cdi) dropped from it's usual 9L/min to less than 4L/min. Suspecting the boiler I called Worcester Bosch for one of their fixed price call outs. The enigineer came and replaced