waagner biro steam boiler

Industrial boilers

Product thermal capacity: 4-35 t/h

Working pressure: 1.0-2.5 MPA

Outlet temperature: 184-350 ℃

Available fuel: natural gas, coke oven gas, bio-gas,liquid propane gas, diesel, heavy oil, light oil, crude oil

Available industries: Petroleum, chemical, chemical fiber, pharmaceutical, textile printing and dyeing, building materials, wood processing, vegetable oil processing and other industries

  • Product introduction
  • Technical advantages
Introduction

waagner biro steam boiler have a three-pass round coil structure. A conical coil is used for the effective protection of the furnace wall at the boiler end. This product is equipped with an advanced combustion device and is fully automated in operation. After the burner ignites the fuel, flame fills the round coil tubes and transfers heat by radiation through the tube wall (first pass). The high temperature flue gas gathers at the back door and then turns to the convection tubes section (second pass), where heat transfer takes place by convection. The flue gas gradually cools down here and flows to the front door, where it is reversed and goes into the third pass. After that, it enters into the chimney through the economizer and is released into the atmosphere.


waagner biro steam boiler.This type of heater is delivered as a whole, and is installed on site, it only needs to connect thermal gas(oil) piping and electricity to start operation. The heater has four heating areas: furnace radiation heating area, the first convection tube bundle heating area, the second convection tube bundle heating area and economizer (waste heat boiler).

Digitized manufacture
  • The laying-off of steel tube adopts CNC 3D laser cutting machine.
  • The manufacture of round coil tube adopts CNC coil tube automatic production line. Once-forming and no need for plastic .
Full argon arc welding
  • The tube butt adopts argon arc welding technique and the seams will be done x ray real-time imaging, preventing unqualified seams from entering coil production line .
Easy operation
  • Heater is wholly assembled before delivery, it is easy for installation, debugging and operating.
  • Fully automatic operating, burning, liquid level of high level tank, outlet temperature and flow rate are adjusted automatically and self-protected.
  • The inlet and outlet with end flanges and flanged cover structure facilitate the installation and layout of tubeline in boiler house.
Less fuel consumption
  • Internal side adopts good insulation material, outside uses stainless steel plate, which can mostly reduce heat lost and make working environment better.
  • Multilayers closely spaced tube bundle and steel rod is used to seal and fix, completely eradicating short circuit of flue gas.
  • Before delivery, the residue moisture is removed completely, so the system draining period is reduced to 2 days from 12 days.
Safely operation
  • The inner coil tube has bigger flow rate, so it is more stable under high temperature operation.
  • Conical coil effectively protects the furnace wall at the end of heater and burner on the top.
waagner biro steam boiler waagner biro steam boiler waagner biro steam boiler

big problem in the boiler tubes..please help. - Boiler an

5/25/2011 · first of all, if the tube is steam cooled , then you have to ensure that there is steam flow whenever the boiler firing rate is over 10% MCR ( or whenever the gas temperature near the tube is over 1000 F) This may require the use of a startup steam bypass valve whenver the main load is not yet available. designer of boiler: Waagner-Biro

lexie@zozen.com > Get A Quote >

Waagner-Biro 160 Years by Waagner Biro - Iss

2/19/2015 · In the years thereafter, Waagner-Biro became one of the main suppliers in the Vienna area in the field of bridge construction, high-rise iron-built projects, as well as grey and cast steel.

lexie@zozen.com > Get A Quote >

Lignite-fired Niederaußem K aims for efficiency of 45 pe

Siemens KWU was selected to supply the supercritical steam turbine and Balcke-Dürr the large cooling towers. Austrian Energy & Environment SGP/Waagner Biro was contracted to supply the flue gas desulphurization (FGD) system and Apparatebau Rothemühle, Brandt + …

lexie@zozen.com > Get A Quote >

Welcome to UB Engineeri

Overview. The O & M Division has serviced more than 30,000 MW of generating capacity since 1980 - an achievement that reflects on the consistency of its workmanship quality and …

lexie@zozen.com > Get A Quote >

ACKM Pithawalla Engineers & Contractors, APB

Erection and Commissioning 150000 lbs/hr X 4 Boiler and 3 X 18 MW turbine with auxiliaries including coal and ash-handling plant, chimney and CW system indoor/outdoor switch gear, pump house etc Erection of one Steam generating Plant & one Turbo generating unit with Pipe & auxiliaries equipment for above Power Plant Waagner-Biro A G

lexie@zozen.com > Get A Quote >

Agios Dimitrios Power Plant - Howling Pix

Agios Dimitrios Power Plant. Agios Dimitrios Power Station is a power plant located near Agios Dimitrios, Kozani, Greece, situated between the towns of Kozani and Ellispontos village. In terms of its location in relation to a metropolis, the plant lies 140 kilometres (87 mi) …

lexie@zozen.com > Get A Quote >

Waagner-Biro 160 Years by Waagner Biro - Iss

—160 YEARS —160 YEARS —CONTENTS— Waagner-Biro Company head office in Margaretenstrasse 70 in the 5th District of Vienna, Austria (from 1877-1979).

lexie@zozen.com > Get A Quote >

ANDRITZ Energy & Environment GmbH: Private Compan

5/27/2019 · ANDRITZ Energy & Environment GmbH designs, manufactures, installs, and services steam generators and air pollution control systems for global industries. It offers fluidized bed boilers, such as

lexie@zozen.com > Get A Quote >

Ghulam Haider Khan Ghory - Design Review Mechanical Eng

View Ghulam Haider Khan Ghory’s profile on LinkedIn, the world's largest professional community. 2 x 326 t/hr High Pressure boilers main steam at 96 bar 510 C manufactured by Waagner Biro

lexie@zozen.com > Get A Quote >

ECOMMISSIONING DISMANTLING DEMOLITION AND CARTING

2 Waagner Biro Steam Boilers rated at 260T/H steam flow fired by Heavy Fuel Oil; 16. Demolition of the boiler will consist of a step-by-step lowering of the body. Prior to decommissioning of the boiler all components such as circuits, oils, etc will be removed. This …

lexie@zozen.com > Get A Quote >

Waagner Biro Gulf LLC | Tel - +971 4 2611528, Duba

Get complete information of Waagner Biro Gulf LLCwith tel- +971 4 2611528, , Dubai at Yellowpages.ae.

lexie@zozen.com > Get A Quote >