manual type steam boiler

Industrial boilers

Product thermal capacity: 4-35 t/h

Working pressure: 1.0-2.5 MPA

Outlet temperature: 184-350 ℃

Available fuel: natural gas, coke oven gas, bio-gas,liquid propane gas, diesel, heavy oil, light oil, crude oil

Available industries: Petroleum, chemical, chemical fiber, pharmaceutical, textile printing and dyeing, building materials, wood processing, vegetable oil processing and other industries

  • Product introduction
  • Technical advantages
Introduction

manual type steam boiler have a three-pass round coil structure. A conical coil is used for the effective protection of the furnace wall at the boiler end. This product is equipped with an advanced combustion device and is fully automated in operation. After the burner ignites the fuel, flame fills the round coil tubes and transfers heat by radiation through the tube wall (first pass). The high temperature flue gas gathers at the back door and then turns to the convection tubes section (second pass), where heat transfer takes place by convection. The flue gas gradually cools down here and flows to the front door, where it is reversed and goes into the third pass. After that, it enters into the chimney through the economizer and is released into the atmosphere.


manual type steam boiler.This type of heater is delivered as a whole, and is installed on site, it only needs to connect thermal gas(oil) piping and electricity to start operation. The heater has four heating areas: furnace radiation heating area, the first convection tube bundle heating area, the second convection tube bundle heating area and economizer (waste heat boiler).

Digitized manufacture
  • The laying-off of steel tube adopts CNC 3D laser cutting machine.
  • The manufacture of round coil tube adopts CNC coil tube automatic production line. Once-forming and no need for plastic .
Full argon arc welding
  • The tube butt adopts argon arc welding technique and the seams will be done x ray real-time imaging, preventing unqualified seams from entering coil production line .
Easy operation
  • Heater is wholly assembled before delivery, it is easy for installation, debugging and operating.
  • Fully automatic operating, burning, liquid level of high level tank, outlet temperature and flow rate are adjusted automatically and self-protected.
  • The inlet and outlet with end flanges and flanged cover structure facilitate the installation and layout of tubeline in boiler house.
Less fuel consumption
  • Internal side adopts good insulation material, outside uses stainless steel plate, which can mostly reduce heat lost and make working environment better.
  • Multilayers closely spaced tube bundle and steel rod is used to seal and fix, completely eradicating short circuit of flue gas.
  • Before delivery, the residue moisture is removed completely, so the system draining period is reduced to 2 days from 12 days.
Safely operation
  • The inner coil tube has bigger flow rate, so it is more stable under high temperature operation.
  • Conical coil effectively protects the furnace wall at the end of heater and burner on the top.
manual type steam boiler manual type steam boiler manual type steam boiler

Boiler Types and Classifications - Wiki - odesie by Tec

Boilers that operate higher than 15 psig are called "high-pressure" boilers. A hot water boiler, strictly speaking, is not a boiler. It is a fuel-fired hot water heater. Because of its similarities in many ways to a steam boiler, the term ''hot water boiler'' is used. Hotwater boilers that have temperatures above 250° Fahrenheit or pressures higher than 160 psig are called ''high temperature hot water boilers''.

lexie@zozen.com > Get A Quote >

Fulton Electric (FB-L) Steam Boiler : User Manu

Installation Component Locations of the Fulton 12 to 1000 kW (1.2 to 100BHP) Steam Boilers 300 to 1000 kW (30 to 100 BHP) Elements are vertically mounted. There boilers have an externally mounted water bottle assembly housing the low water cutoff probe, pump on and pump off probe.

lexie@zozen.com > Get A Quote >

Installation and Operating Service Manual - bryanboilers.c

Blowdown valve(s) must be full size of the connection on the boiler. Steam boilers 15 psig and below require at least one blowdown valve. Higher-pressure boilers require two blowdown valves with one or both valves being slow opening type. Each water column and float type low water cut-off must be equipped with a blowdown valve.

lexie@zozen.com > Get A Quote >

Installation Operation Service Manual - Bryan Ste

connection on the boiler. Steam boilers 15 psig and below require at least one blowdown valve. Higher pressure boilers require two blowdown valves with one or both valves being slow opening type. Each water column and float type low water cut-off must be equipped with a …

lexie@zozen.com > Get A Quote >

www.equipnet.c

The complete packaged steam boiler is listed as a standard with UL, the CSA, and the CGA, and it can be tuned to meet FM and/or ASME- CSD1 requirements at the customer’s request. Please note that …

lexie@zozen.com > Get A Quote >

Boiler Manual • Installation • Maintenance • Startup • Par

OIL-FIRED NATURAL DRAFT STEAM BOILER — SERIES 3 — Boiler Manual HOMEOWNER and SERVICE TECHNICIAN — read and follow completely. Operation SGO with float-type low water cutoff 1. If burner does not fire, check for: • Switch on boiler or additional shut-off switches turned off. • Fuses or breaker switch tripped.

lexie@zozen.com > Get A Quote >

List of boiler types, by manufacturer - Wikiped

Sometimes small return-tube boilers of just this form are also described as "launch-type". Lentz boiler A large launch-type boiler with a corrugated furnace, used rarely for some steam locomotives. Of German design. A similar boiler, the Vanderbilt, was used in the USA. Locomobile steam-car boiler

lexie@zozen.com > Get A Quote >

OPERATING AND MAINTENANCE MANUAL FOR BOILER

Manual Release Lever Temperature Probe 4. Install a relief valve overflow pipe to a nearby floor drain. CAUTION: No valve of any type should be installed between the relief valve and tank or in the drain line. 5. On heaters supplied with the optional anticipator system, open the ¼” needle valve on the cold water inlet anticipator line.

lexie@zozen.com > Get A Quote >

Boiler Manual - Union Steam | Boile

Boiler Manual GWI Gas-Fired Water Boilers This manual must only be used by a qualified heating installer/service technician. Failure to comply could result in severe personal injury, death or substantial property damage. When calling or writing about the boiler— Please have: • boiler model number from the boiler rating label and • CP numbe r

lexie@zozen.com > Get A Quote >

CIBO Energy Efficiency Handbo

he Energy Efficiency Handbook was pre-pared to help owner/operators get the best and most energy-efficient perform­ ance out of their boiler systems. This manual gives information and helpful operational tips on virtually every aspect of boiler operation, from Water Treatment, through Combustion and Heat

lexie@zozen.com > Get A Quote >

Volume 1, Steam Boilers - Steam, Heating Hot Water, an

1.1.4 Steam boilers and associated equipment whether central or decentralized shall be located in a secure, conditioned, and protected building and shall provide the appropriate security and weather protection in all climates.

lexie@zozen.com > Get A Quote >